4.5 PMP System Status Screen
Click System Status in the main menu to view system, Ethernet statistics, and wireless
interface statistics.
Fig. 20: Web - PMP System Status Screen
The following fields are specific to operation in PMP mode. See 3.3: PTP System Status
Screen on page 28 for information on all other fields.
Configured Stations: Number of Links defined (to subscribers).
Configured Connections: Number of Connections defined for all subscribers.
Active Wireless Links: The number of registered subscribers.
Active Wireless IDs: The number of connections to registered subscribers.
Current Tx Power: The current transmit power level.
Current Frequency: Current RF channel frequency.