Redline Communications RDL-2000 Manual de Serviço Página 36

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 52
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 35
RDL-2000 Installation Guidelines
70-00144-01-01 Proprietary Redline Communications © 2011 Page 36 of 52 March 9, 2011
Table 10: Outdoor Line Protection Wiring Diagram
Terminal Block (TB) Signal Color Code Wire Color
1 Rx + White / Orange
2
Rx -
Orange
3
Tx +
White / Green
4 Tx - Green
5 48 (+) Blue
6 48 (+) White/Blue
7 48 (-) White/Brown
8
48 (-)
Brown
Line Protector Mast Mounting Kit
This kit is used for mounting the lightning protector to a 76 - 127 mm (3-5 in) diameter pole.
Note: The Polyphaser IX-Pole-Kit kit is not available directly from Redline, and must be
ordered separately (if required) from a telecom equipment distributor.
1. Align box cover plate (1) mounting holes (Pemstuds facing out) with mounting holes on the
LP box.
2. Insert screws (2) through the LP box and cover (1), secure with #8 washer (5) and nut (4).
3. Attach bracket (3) onto Pemstuds of assembly cover (1) using #10 washer (7) and nut (6).
4. Slide hose clamp (8) through both slotted grooves of bracket (3), attach hose clamp to pole.
Figure 24: Lightning Protection - Mounting Kit
Table 11: Lightning Protection - Mounting Kit Parts List
Item Description Qty. Item Description Qty.
1 Assm Bracket 1 5 Washer #8 int. 2
2 Screw 8-32 x 0.5 2 6 Nut #10 2
3 Bracket Mnl Dbl Bend 1 7 Washer #10 2
4 Nut #8 2 8 Clamp Hose 3-5 in. 1
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
Vista de página 35
1 2 ... 31 32 33 34 35 36 37 38 39 40 41 ... 51 52

Comentários a estes Manuais

Sem comentários