Redline Communications RDL-2000 Manual do Utilizador Página 46

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 45
RDL-2000 User Manual
70-00143-01-01 Proprietary Redline Communications © 2011 Page 46 of 52 March 9, 2011
maximum of 16 bytes, and include only alphanumeric characters (a-z, 0-
9). This field is used only when AES is enabled. Identical encryption
settings must be used on the Master and Slave.
Example: Use the following command to enable AES on the Master.
[192.168.25.2] >>:aes on SharedKey123
aes on SharedKey123
Important: The Master and Slave RDL-2000 units must
have identical encryption
settings or the system will not establish a wireless link
.
atpc <off> <on> <power>
View or change the automatic transmit power control (ATPC) mode settings.
[blank] - Display current mode/setting.
Master: Display current ATPC RSSI level.
Slave: Display current Tx power level.
off - Disable ATPC.
on - Enable ATPC.
power - Enter the target Rx power threshold (dBm).
Example: Use the following command to enable ATPC on the Master and set the
RSSI threshold of the link to -60 dBm.
[192.168.25.2] >>:atpc on -60
autorate <off> <on>
View or change the adaptive modulation settings. When adaptive modulation is
disabled, the RDL-2000 will transmit using only using the selected
modulation/coding (see rate command). When adaptive modulation is enabled,
the modulation/coding is adjusted automatically based on current link conditions.
[blank] - Display current mode/setting.
off - Disable adaptive modulation.
on - Enable adaptive modulation.
Example: Enable adaptive modulation on the master:
[192.168.25.2] >>:autorate on
MU autorate
autorate on
extsync
This function not supported in this release.
firmware <[blank] | file.brn>
View the firmware versions or upload a new binary file. The RDL-2000 contains
non-volatile storage for two versions of the software. The upload function
overwrites the non-operational version.
[blank] - Display current software versions. The text 'FFFF FFFF' indicates that
no software is loaded in the alternate bank.
binary - Full name of binary file (including.bin extension). A TFTP server must be
installed and running on the computer running the Telnet session.
To upgrade the firmware, the computer hosting the Telnet session must
also have a TFTP server. The firmware file must be located in the TFTP
servers default directory (can not specify a path). When the transfer has
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299